CFD-Based Scale-Up Analysis of Airlift Photobioreactors: Effects of Superficial Gas Velocity on Hydrodynamics and Mass Transfer
Volume 23, Issue 2, Summer 2026, Pages 3-25
https://doi.org/10.22034/ijche.2026.590277.1603
Mir Mehrshad Emamshoushtari, Farshid Pajoum Shariati, Omid Tavakoli, Michael Harasek, Bahram Haddadi Sisakht
Abstract Maintaining a constant superficial gas velocity (Usg) is the most common criterion for scaling aerated photobioreactors, yet whether it preserves gas–liquid hydrodynamics is rarely tested directly. Euler–Euler CFD was used to characterize two baffled airlift reactors, a 9.7 L laboratory unit and a 106 L scaled-up unit, over the Usg = 0.025–0.10 m·s⁻¹, evaluating gas holdup, the gas-phase velocity, and the volumetric mass transfer coefficient (kLa) alongside the Reynolds number, Froude number, and power input per unit volume (P/V). Across this range, gas holdup rose 2.4–2.6-fold and kLa rose 1.3–1.6-fold in both reactors, but the mean gas velocity increased more in the larger unit (1.4-fold vs. 1.1-fold). The extended-range simulations of the large reactor showed continued but progressively less proportional gains. The Froude number was not conserved across scales, and P/V remained consistently higher in the larger reactor. These results show that Usg alone is an insufficient scale-up criterion, gas holdup, the kLa, Froude number, and P/V should be evaluated jointly.