<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Iranian Association of Chemical Engineering (IAChE)</PublisherName>
				<JournalTitle>Iranian Journal of Chemical Engineering (IJChE)</JournalTitle>
				<Issn>1735-5397</Issn>
				<Volume>15</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2018</Year>
					<Month>11</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Propionic acid extraction in a microfluidic system: simultaneous effects of channel diameter and fluid flow rate on the flow regime and mass transfer</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>48</FirstPage>
			<LastPage>62</LastPage>
			<ELocationID EIdType="pii">80765</ELocationID>
			
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>F.</FirstName>
					<LastName>Hosseini</LastName>
<Affiliation>CFD Research Center, Chemical Engineering Department, Razi University, Kermanshah, Iran</Affiliation>

</Author>
<Author>
					<FirstName>M.</FirstName>
					<LastName>Rahimi</LastName>
<Affiliation>CFD Research Center, Chemical Engineering Department, Razi University, Kermanshah, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-1144-9351</Identifier>

</Author>
<Author>
					<FirstName>O.</FirstName>
					<LastName>Jafari</LastName>
<Affiliation>CFD Research Center, Chemical Engineering Department, Razi University, Kermanshah, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>06</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		<Abstract>In this work, extraction of propionic acid from the aqueous phase to the organic phase (1-octanol) was performed in T-junction microchannels and effects of channel diameter and fluid flow rate on the mass transfer characteristics were investigated. The two-phase flow patterns in studied microchannels with 0.4 and 0.8 mm diameters were observed. Weber ‎ number and surface-to-volume ratio were calculated for evaluating flow patterns. Moreover, the effect of volumetric flow rates on the extraction ‎efficiency, volumetric mass transfer coefficient, and pressure drop was examined. Results showed that the pressure drop in the microchannel with 0.4 mm diameter is 2-2.7 times higher than that in the microchannel with 0.8 mm diameter. In both microchannels, with increase in flow rate, the extraction ‎efficiency first increases and then decreases. In addition, at high flow rates (2.4, 4.5 and 6 mL/min), the extraction ‎efficiency in the microchannel with 0.8 mm diameter increased up to the range of 7-14.9 % compared with that in the microchannel with 0.4 mm diameter.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Extraction</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">propionic acid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">microfluidic</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Channel Diameter</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.ijche.com/article_80765_d7e576ddd613b33a3ec6b0c14a58ff8c.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
